Bảng mã lỗi Servo Delta và hướng dẫn sửa chữa

Mã lỗi hiển thị

Thông tin chi tiết lỗi

AL001

Overcurrent

AL002

Overvoltage

AL003

Undervoltage

AL004

Motor combination error

AL005

Regeneration error

AL006

Overload

AL007

Excessive deviation of Speed command

AL008

Abnormal pulse command

AL009

Excessive deviation of Position command

AL010

Voltage error during regeneration

AL011

Encoder error

AL012

Adjustment error

AL013

Emergency stop

AL014

Reverse limit error

AL015

Forward limit error

AL016

Abnormal IGBT temperature

AL017

Abnormal EEPROM

AL018

Abnormal encoder signal output

AL020

Serial communication timeout

AL022

RST leak phase

AL023

Early overload warning

AL024

Encoder initial magnetic field error

AL025

Encoder internal error

AL026

Encoder unreliable internal data

AL027

Encoder internal reset error

AL028

Encoder voltage error or encoder internal error

AL029

Gray code error

AL030

Motor crash error

AL031

Motor power cable wiring error / disconnection

AL034

Encoder internal communication error

AL035

Encoder temperature exceeds the protective
range

AL042

Analog input voltage is too high

AL044

Servo function overload warning

AL045

E-Gear ratio value error

AL053

Motor parameters are not confirmed

AL056

Excessive motor speed

AL05C

Motor position feedback error

AL060

Absolute position is lost

AL061

Encoder undervoltage

AL062

Number of turns for the absolute encoder
overflows

AL067

Encoder temperature warning

AL068

Absolute data transmitted by I / O is in error

AL069

Wrong motor type

AL06A

Absolute position is lost

AL070

Encoder did not complete the set-up command
issued by servo drive

AL072

Encoder overspeed

AL073

Encoder memory error

AL074

Encoder single-turn absolute position error

AL075

Encoder absolute number of turns is in error

AL077

Encoder internal error

AL079

Encoder parameter error

AL07B

Encoder memory busy

AL07C

Command to clear the absolute position is issued
when the motor speed is over 200 rpm

AL07D

Motor stops operating when servo drive power is
cycled before AL07C is cleared

AL07E

Encoder clearing procedure error

AL07F

Encoder version error

AL083

Servo drive outputs excessive current

AL085

Regeneration error

AL086

Input voltage is too high

AL088

Servo function operational warning

AL089

Current detection interference

AL08A

Auto-tuning function – command error

AL08B

Auto-tuning function – pause time is too short

AL08C

Auto-tuning function – inertia estimation error

AL099

DSP error

AL521

Vibration elimination parameter error

AL35F

Emergency stop during deceleration

AL3CF

Emergency stop

AL207

Parameter group of PR # 8 is out of range

AL209

Parameter number of PR # 8 is out of range

AL213

Parameter setting of PR # 8 is in error

AL215

Write parameters : read-only

AL217

Write parameters : parameter locked

AL231

Monitoring item of PR # 8 is out of range

AL235

Position counter overflow warning

AL237

Indexing coordinate is undefined

AL245

PR positioning timeout

AL249

PR number exceeds the range

AL283

Software positive limit

AL285

Software negative limit

AL289

Position counter overflows

AL380

Position offset alarm for DO.MC _OK

AL3F1

Communication type absolute position command
error

AL400

Indexing coordinate setting error

AL404

Value of PR special filter setting is too high

AL555

System failure

AL809

PR motion setting error or command decoding
error

AL500

STO function is enabled

AL501

STO_A lost ( signal loss or signal error )

AL502

STO_B lost ( signal loss or signal error )

AL503

STO self-diagnostic error

Source: https://vvc.vn